ELEVATOR CAB AC, DC FANS AND PARTS

FANS, AC
Elevator cab AC fans engineered for maximum air distribution. Our fans are totally enclosed, pre-lubricated, easy to install, quiet and dependable.

Available with 115VAC or 220VAC single or two speed motor and 5-blade fan.

Durable cages made from 16-gauge welded steel.
Round cages are galvanized, square fans - black powder coated.

Elevator Cab Fans PDF flyer
SSF3, SSFE,
TSF1, TSFE

SSF3C,
TSF1C

SSF3R, TSFE1420
TSFE1421, TSFE1424

  Square Fans, AC

Speed CFM* Voltage Cage Dimensions Cage Opening
Model SSF3 Single speed 380 115VAC, 50-60 Hz 12” x 12” x 4-1/4” H 10” x 10”
Model SSF3C** Single speed 380 115VAC, 50-60 Hz 12” x 12” x 4-1/4” H 10” x 10”
Model SSFE Single speed 325 220VAC, 50-60 Hz 12” x 12” x 4-1/4” H 10” x 10”
Model TSF1 Two speed 345-300 115VAC, 50-60 Hz 12” x 12” x 4-1/4” H 10” x 10”
Model TSF1C** Two speed 345-300 115VAC, 50-60 Hz 12” x 12” x 4-1/4” H 10” x 10”
Model TSFE Two speed 325-290 220VAC, 50-60 Hz 12” x 12” x 4-1/4” H 10” x 10”
* Approximate CFM values. ** 7/16” Dia. cage holes to comply with California code.
Lip 1” wide with four (4) mounting holes, 11” center to center.

   Round Fans, AC

Speed CFM* Voltage Cage Dimensions Cage Opening
Model SSF3R Single speed 380 115VAC, 50-60 Hz 14” Dia. x 4-1/2” H 12” Dia.
Model TSFE1421 Two speed 325 115VAC, 50-60 Hz 12” Dia. x 4-1/2” H 10” Dia.
Model TSFE1424 Two speed 325 115VAC, 50-60 Hz 14” Dia. x 3-1/2” H 12” Dia.
Model TSFE1420 Two speed 325 115VAC, 50-60 Hz 14” Dia. x 4-1/2” H 12” Dia.
* Approximate CFM values.
Lip 1” wide with four (4) mounting holes, 13” center to center, and 11” for TSFE1421.

   AC Fans Replacement Parts

Model 21FN001 Single speed AC fan motor
Model 21FN002 Two speed AC fan motor
Model A01FN001 Two speed suction blade
Model A01FN002 Single speed suction blade
Model A01FN003 Single/Two speed push blade
FANS, DC
STAND-BY EMERGENCY VENTILATION FOR GLASS ELEVATORS

Ideal for use in glass elevators exposed to direct sunlight.
Our fans with emergency power source is designed to exceed the minimum ANSI A17.1- 2004 Section 2.14.2.3.3(b) requirement of one hour.
Durable cages made from 16-gauge welded steel, black powder coated. NOTE: Not intended as primary ventilation.

Elevator Cab Fans PDF flyer
SSF4DC
SSF4C
PP/SSF4DC
PP/SSF4DC-1
 
Square DC Fan With Power Supply
Model SSF4DC
• Square fan with 12VDC motor and 120VAC/12VDC or 220VAC/12VDC 50-60Hz power supply
• Single speed, 300 CFM free air
• Cage dimensions 12” x 12” x 4-1/4”, cage opening 10” x 10”
• Lip 1” wide with four (4) mounting holes, 11” center to center

Bulb type thermostat operates the fan when elevator temperature reaches 80 and shuts off when temperature decreases to 75, allowing greater time frame for emergency operation.


Replacement DC Fan

Model SSF4C

• Square fan with 12VDC motor, no power supply included
• 300 CFM free air
• Cage dimensions 12” x 12” x 4-1/4” H, cage opening 10” x 10”

• Lip 1” wide with four (4) mounting holes, 11” center to center


Replacement Emergency Power Supply

Model PP/SSF4DC      120VAC/12VDC
Model PP/SSF4DC-1   220VAC/12VDC

• Sealed lead acid batteries for uniform discharge performance
• Solid state charging system constantly maintains battery charge
• Charging system 12" x 12" x 6" can be mounted horizontally or vertically
• Four hour power supply
• Test switch, indicator charging lights

In the event of a power failure, the power supply will restore the charge at the rate of eight hours for every four hours of discharge. Bulb type thermostat operates the fan when elevator temperature reaches 80 and shuts off when temperature decreases to 75, allowing greater time frame for emergency operation.