POWER UNITS |
|
|
POWER UNITS DIMENSIONS |
|||||
TANK |
PUMP | H.P. |
G.P.M. |
MAXIMUM OIL |
TANK DIMENSIONS |
SK-32 |
187M 14043 |
15 20 |
67 70 |
1-1/2 70 GPM | 32W x 18D x 36H |
| 187 14046 |
15 20 25 |
79 80 |
2 134 GPM | ||
| 217P 21040 |
20 25 30 |
98 96 |
|||
SK-36 |
21043 217M |
25 30 40 |
104 106 |
2 134 GPM | 36W x 18D x 42H |
| 21046 217 |
25 30 40 |
121 123 |
|||
| SK-48 | 28043 236G |
25 30 40 |
141 144 |
2-1/2 206 GPM | |
| 28046 236G |
30 40 50 |
162 163 |
48W x 23D x 48H | ||
| 280-51 236AS 440-40 |
40 50 60 |
184 190 200 |
|||
| 275E | 40 |
217 |
3 270 GPM |
||
|
|||||
POWER UNITS TECHNICAL DATA |
|
| Voltage Available | 3 Phase 60Hz, 200V, 230V, 460V, and 575V. |
| Working Pressure | 200-400 PSI. |
| Pump Type |
Positive displacement rotating screw IMO or ALWEILER pump Maxton UC-4, UC4M, UC1A or EECO UV-5A, UV-7B. |
| Single units average weight | 400 to 700 lb. |
| Model SK-32 | Requires 35 gallons of permanent oil and has 38 gallons of transferable oil. |
| Model SK-36 | Requires 38 gallons of permanent oil and has 60 gallons of transferable oil. |
| Model SK-48 | Requires 76 gallons of permanent oil and has 122 gallons of transferable oil. |
| Model SK-60 | Requires 159 gallons of permanent oil and has 215 gallons of transferable oil. |
| Model SK-72 | Requires 202 gallons of permanent oil and has 258 gallons of transferable oil. |
|
|